Quadruple Automation Services
Solutions PLC & SCADA Systems
Siemens • Allen-Bradley • Beckhoff • Ignition Gold Partner

Expert PLC &
SCADA Engineering
For Any Platform.

QAS engineers program, commission and modernise PLC and SCADA systems across all major platforms — Siemens, Allen-Bradley, Beckhoff, Schneider and more. New builds, upgrades, migrations and multi-vendor integrations.

15+
Years PLC Experience
All
Major PLC Brands
ISA-18.2
Alarm Standards
24/7
Remote Support
QAS SCADA — Plant Control Overview
RUNNING
PLC & Controller Status
Siemens S7-1515
Line 1 Main
RUN
A-B ControlLogix
Assembly Cell
RUN
Beckhoff CX5230
Conveyor Sys
RUN
Siemens S7-1212
Safety Zone
RUN
Schneider M340
Utilities
IDLE
A-B CompactLogix
Paint Booth
FAULT
Live Process Values
Line Speed 18.4 m/min
Conveyor Load 74%
System Pressure 6.2 bar
Cycle Time 38.2 sec

Every Major PLC & SCADA
Platform. One Team.

Our engineers are trained and certified across all major control system brands — so you never need a different vendor for a different PLC.

Allen-Bradley / Rockwell

ControlLogix • CompactLogix • MicroLogix • FactoryTalk View • Studio 5000

Studio 5000 / RSLogix
ControlLogix & CompactLogix
FactoryTalk View SE/ME
GuardLogix safety
EtherNet/IP
FactoryTalk Historian

Siemens

S7-300 / S7-400 / S7-1200 / S7-1500 • TIA Portal • WinCC • Simatic HMI

TIA Portal programming
S7-1200 / 1500 / 300 / 400
WinCC SCADA & HMI
Safety (F-PLC)
Profinet & Profibus
OPC-UA server

Mitsubishi & Omron

MELSEC iQ-R / Q / F • Omron NX / NJ • GX Works • Sysmac Studio

GX Works 3 programming
MELSEC iQ-R series
Omron Sysmac Studio
NX / NJ controllers
CC-Link IE
GOT HMI series

FactoryTalk View (FT View)

Rockwell Automation • FT View SE • FT View ME • PanelView Plus

FT View SE (supervisory)
FT View ME (machine-level)
PanelView Plus HMI
FactoryTalk Alarms & Events
FactoryTalk Historian
RSLinx OPC-DA / OPC-UA

FT Optix

Rockwell Automation • FactoryTalk Optix • Modern HMI • Web-Based

Web-based HMI & SCADA
HTML5 cross-platform UI
C# scripting engine
Unified namespace ready
Cloud & edge deployment
Native Logix integration

Ignition SCADA

Inductive Automation • Unlimited Licensing • Web-Based • Gold Certified

Gold Certified Partner
Unlimited tag licensing
Web-based HMI screens
Built-in historian
MES & ERP integration
Mobile & responsive UI

What We Engineer for You

From greenfield PLC programming to brownfield SCADA modernisation — our engineering team covers the full control system lifecycle.

PLC Programming

Structured, documented PLC programs in Ladder, FBD, ST and SFC — following IEC 61131-3 standards. New builds, modifications and reverse engineering of legacy programs.

IEC 61131-3 compliant code Ladder / FBD / ST / SFC Full code documentation Revision control Factory acceptance testing

SCADA & HMI Development

Intuitive SCADA screens and HMI panels on Ignition, WinCC, FactoryTalk and Vijeo Citect — with live process visualisation, alarm management and historical trending.

Ignition / WinCC / FT View Process mimic screens Alarm management Trend & historical views Mobile-responsive HMI

Control System Upgrades

Migration of obsolete PLCs (S5, SLC 500, PLC-5) to modern platforms — with full I/O mapping, program conversion and commissioning. Minimum production downtime.

S5 → S7 migration SLC 500 → ControlLogix I/O mapping & rewiring Program conversion Hot-cutover planning

Alarm Management

ISA-18.2 alarm rationalisation, priority management and shelving — reducing nuisance alarms by up to 70% so operators focus on what matters.

ISA-18.2 compliance Alarm rationalisation Priority & classification Shelving & suppression Alarm performance KPIs

Safety Systems (SIL)

Safety-rated PLC programming (GuardLogix, S7-F, PILZ) — SIL 2/3 compliant, IEC 62061 and EN ISO 13849 machinery safety with full functional safety documentation.

SIL 2 / SIL 3 rated GuardLogix & S7-F IEC 62061 / EN 13849 LOPA & risk assessment Safety validation report

Remote Access & Support

Secure VPN-based remote access to your control systems — 24/7 troubleshooting, program modifications and SCADA support without waiting for an engineer on site.

Secure VPN access 24/7 remote support PLC fault diagnosis SCADA modifications Response SLA guaranteed

Ageing System vs Modernised Control

What changes when you replace obsolete PLCs and paper-based control with modern, connected systems engineered by QAS.

Ageing / Legacy System
QAS Modernised System
Spare parts unavailable, engineer knowledge lost, vendor support ended years ago
Obsolescence
Modern platform with long-term vendor support, full documentation and available spares
Hundreds of nuisance alarms — operators ignore the alarm panel entirely
Alarm Management
ISA-18.2 rationalised alarms — only meaningful alerts, properly prioritised
Operators use paper logbooks and wall-mounted indicator lights to understand plant state
Visibility
Full SCADA overview — process values, trends and alarms on modern colour HMI screens
Fault finding requires an engineer on site with old documentation and a laptop adapter
Diagnostics
Remote VPN access — faults diagnosed and often fixed without an engineer visit
PLC data is isolated — no connection to MES, ERP or historian
Integration
OPC-UA and MQTT feed real-time data to MES, ERP, historian and dashboards
Recipe changes require manual parameter entry at multiple HMI screens — error-prone
Changeovers
Digital recipe management — one-click changeover with validation and audit trail
70%
Alarm Reduction
ISA-18.2 rationalisation
+15%
Uptime Improvement
Modern reliable hardware
−50%
Fault Response Time
Remote access & diagnostics
100%
Data Connectivity
OPC-UA to MES & ERP

How We Deliver Every Project

01
01

Engineering Review

We review existing PLC code, I/O lists, P&IDs and SCADA screens. Any gaps are identified and documented before engineering starts.

02
02

Design & FAT

Full system design — program structure, HMI layouts, alarm philosophy. Factory Acceptance Test completed before shipping.

03
03

Commission & SAT

On-site installation, wiring checks and Site Acceptance Test. Parallel run where required. Zero production surprises.

04
04

Handover & Support

Full documentation package, operator training and 24/7 remote support from day one. You own every line of code.

Engineering Standards We Follow

IEC 61131-3 ISA-18.2 IEC 62061 EN ISO 13849 ISA-88 ISA-95 IEC 61511 (SIL) NFPA 79

Obsolete PLC? Unreliable SCADA?
We Fix It — Fast.

Talk to a QAS control systems engineer. We will review your existing setup, identify the risks and recommend the fastest path to a modern, reliable system — with minimum production disruption.

Response within 24 hours Free system audit included No obligation
Chat with us